Laser Unit > Qualified IR Pulsed Laser with Negative Chirp for Multiphoton Excitation | Mode-locked Ti: sapphire laser [femtosecond laser (equipped with a group velocity compensation)], laser power unit, water-cooled circulating chiller
MaiTai BB DeepSee-OL, MaiTai HP DeepSee-OL or MaiTai eHP DeepSee-OL (Spectra-Physics products)
Chameleon Vision I-OL, Chameleon Vision II-OL (Coherent products)
| |
---|---|---|
Laser Unit > Automatic Introduction Optic |
AOTF (B, S, T system)
| |
Laser Unit > Optional Visible Light Laser for Stimulation |
LD473 laser (15 mW) Depending on the type of modulation: light intensity modulation, shutter control, connected to the
| |
Laser Unit > LD Laser for Visible Light > 405 nm |
| |
Laser Unit > LD Laser for Visible Light > 440 nm |
| |
Laser Unit > LD Laser for Visible Light > 473 nm |
| |
Laser Unit > LD Laser for Visible Light > 559 nm |
| |
Laser Unit > LD Laser for Visible Light > 635 nm |
| |
Laser Unit > Multiline Argon Laser (457 nm, 488 nm, 515 nm, Total 30 mW) |
| |
Laser Unit > HeNe(G) Laser (543 nm, 1 mW) |
| |
Scanning and Detection > Main Scanner > Standard Laser Ports |
| |
Scanning and Detection > Main Scanner > Detector > Standard |
| |
Scanning and Detection > Main Scanner > Detector > Cooled GaAsP-PMT 2 CH |
| |
Scanning and Detection > Main Scanner > Detector > Optional 4 CH |
| |
Scanning and Detection > Main Scanner > Photo Detection Method > Analog Integration |
| |
Scanning and Detection > Main Scanner > Photo Detection Method > Hybrid Photon Counting |
| |
Scanning and Detection > Main Scanner > VIS - UV - IR Excitation Dichromatic Mirror Turret |
| |
Scanning and Detection > Main Scanner > Beamsplitter Turrets |
| |
Scanning and Detection > Main Scanner > Wavelength Selection |
<Spectral type> (B, S, T system)
| |
Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Galvanometer Mirror Scanner (X, Y) |
| |
Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Modes > 2D |
<Spectral type>
| |
Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Modes > 3D |
<Spectral type>
| |
Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Modes > 4D |
<Spectral type>
| |
Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Modes > 5D |
<Spectral type>
| |
Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Modes > Other | Line scanning: Straight line with free orientation, free line, Point scanning | |
Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Speed |
| |
Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Pinhole |
<Spectral type>
| |
Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Zoom |
| |
Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Modes > 2D | - | |
Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Modes > 3D | - | |
Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Modes > 4D | - | |
Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Modes > 5D | - | |
Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Modes > other | - | |
Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Speed | - | |
Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Zoom | - | |
Scanning and Detection > Field Number (NA) |
| |
Scanning and Detection > Z-Drive |
| |
Scanning and Detection > Transmitted Light Detector Unit |
Photomultiplier (2 channels), fluorescent detector Fluorescence wavelength can be selected with the dedicated filter cube (replaceable)
| |
Microscope > Frame |
| |
Microscope > Frame > Inverted |
| |
Microscope > Objectives and Focus > Objectives |
| |
Microscope > Objectives and Focus > Auto Focus (AF) |
| |
Microscope > Objectives and Focus > Water Supply |
| |
Microscope > Objectives and Focus > Oil Supply |
| |
Microscope > XY Stage > Specimen Holder |
| |
Microscope > Incubator > Room Environment |
| |
Microscope > Incubator > Heating Method |
| |
System Control > Controller |
| |
System Control > Power Supply Unit | - | |
System Control > Monitor |
| |
Optional Unit > SIM Scanner |
| |
Optional Unit > TIRFM Unit |
| |
Software > Image Acquisition | - | |
Software > Programmable Scan Controller | - | |
Software > 2D Image Display | - | |
Software > 3D Visualization and Observation | - | |
Software > Image Format | - | |
Software > Spectral Unmixing | - | |
Software > Image Processing | - | |
Software > Image Analysis | - | |
Software > Statistical Processing | - | |
Software > Optional Software | - | |
Software > Image Acquisition Mode | - | |
Software > Map Image Acquisition | - | |
Software > Multi Area Time-Lapse | - | |
Software > Image Acquisition Area | - | |
Software > Image Display |
| |
Software > Cross Talk Reduction | - | |
Software > Acquisition Image File Type |
| |
Software > Image File Type Available for Viewing |
| |
Software > Image Editing | - | |
Software > 3D Image Construction | - | |
Software > Basic Features | - | |
Software > IR Laser Controlling |
| |
Software > Optional Motorised-Stage Software | - | |
Software > Optional Mapping and Multiplepoint Simulation Software | - | |
Software > Optional Sequencer Manager | - | |
Dimensions, Weight and Power Consumption > Microscope with Scan Unit > Dimensions (mm) |
| |
Dimensions, Weight and Power Consumption > Microscope with Scan Unit > Weight (kg) |
| |
Dimensions, Weight and Power Consumption > Microscope with Scan Unit > Power Consumption |
| |
Dimensions, Weight and Power Consumption > Fluorescence Illumination Unit > Dimensions (mm) |
| |
Dimensions, Weight and Power Consumption > Fluorescence Illumination Unit > Weight (kg) |
| |
Dimensions, Weight and Power Consumption > Fluorescence Illumination Unit > Power Consumption |
| |
Dimensions, Weight and Power Consumption > Transmitted Light Detection Unit > Dimensions (mm) |
| |
Dimensions, Weight and Power Consumption > Transmitted Light Detection Unit > Weight (kg) |
| |
Dimensions, Weight and Power Consumption > Transmitted Light Detection Unit > Power Consumption |
| |
Dimensions, Weight and Power Consumption > Microscope Control Unit > Dimensions (mm) |
| |
Dimensions, Weight and Power Consumption > Microscope Control Unit > Weight (kg) |
| |
Dimensions, Weight and Power Consumption > Microscope Control Unit > Power Consumption |
| |
Dimensions, Weight and Power Consumption > FV Power Supply Unit > Dimensions (mm) |
| |
Dimensions, Weight and Power Consumption > FV Power Supply Unit > Weight (kg) |
| |
Dimensions, Weight and Power Consumption > FV Power Supply Unit > Power Consumption |
| |
Dimensions, Weight and Power Consumption > Power Supply Unit for Laser Combiner > Dimensions (mm) |
| |
Dimensions, Weight and Power Consumption > Power Supply Unit for Laser Combiner > Weight (kg) |
| |
Dimensions, Weight and Power Consumption > Power Supply Unit for Laser Combiner > Power Consumption |
| |
Dimensions, Weight and Power Consumption > Laser Combiner (with Ar Laser Heads) > Dimensions (mm) |
| |
Dimensions, Weight and Power Consumption > Laser Combiner (with Ar Laser Heads) > Weight (kg) |
| |
Dimensions, Weight and Power Consumption > Laser Combiner (with Ar Laser Heads) > Power Consumption |
| |
Dimensions, Weight and Power Consumption > Laser Combiner (without Ar Laser Heads) > Dimensions (mm) |
| |
Dimensions, Weight and Power Consumption > Laser Combiner (without Ar Laser Heads) > Weight (kg) |
| |
Dimensions, Weight and Power Consumption > Laser Combiner (without Ar Laser Heads) > Power Consumption |
| |
Dimensions, Weight and Power Consumption > LD559 Laser Power Supply > Dimensions (mm) |
| |
Dimensions, Weight and Power Consumption > LD559 Laser Power Supply > Weight (kg) |
| |
Dimensions, Weight and Power Consumption > LD559 Laser Power Supply > Power Consumption |
| |
Dimensions, Weight and Power Consumption > Multi Ar Laser Power Supply > Dimensions (mm) |
| |
Dimensions, Weight and Power Consumption > Multi Ar Laser Power Supply > Weight (kg) |
| |
Dimensions, Weight and Power Consumption > Multi Ar Laser Power Supply > Power Consumption |
| |
Dimensions, Weight and Power Consumption > HeNe(G) Laser Power Supply > Dimensions (mm) |
| |
Dimensions, Weight and Power Consumption > HeNe(G) Laser Power Supply > Weight (kg) |
| |
Dimensions, Weight and Power Consumption > HeNe(G) Laser Power Supply > Power Consumption |
| |
Dimensions, Weight and Power Consumption > Operating Environment (Indoor Use) > Ambient Temperature | Room temperature: 20 - 25 ℃ | |
Dimensions, Weight and Power Consumption > Operating Environment (Indoor Use) > Maximum Relative Humidity | 75 % or less at 25 °C requires continuous (24-hour) power supply |
Sorry, this page is not
available in your country.