Evident LogoOlympus Logo
Application Notes

Application of silicone immersion objectives to long-term 3D live-cell imaging of mouse embryo during development


Long-term 3D live-cell imaging of a mouse embryo during development

Advances in microscopy have revealed numerous phenomena that occur during embryonic development, and this has become a major research focus in the field of developmental biology. In particular, as confocal microscopes have come into more general use, this has enabled researchers to obtain sharp three-dimensional fluorescence images of proteins, DNA, and other molecules in the zygote and of individual cells during embryonic development.
With research in this area making rapid progress, confocal microscopy is being used for prolonged 3D live-cell imaging to capture dynamic change over time as well as for three-dimensional fluorescence imaging. Olympus developed silicone immersion objectives that enable high-contrast[PG1] , long-term 3D live-cell imaging.
This application note introduces an example of high-contrast 3D live-cell imaging during the in vitro development of a mouse embryo from the zygote to blastocyst stage over approximately 4 days using a silicone immersion objective.
This application note is based on a study conducted by Dr. Kazuo Yamagata, Associate Professor in the Department of Genetic Engineering, Faculty of Biology-Oriented Science and Technology at Kinki University and his collaborators that was published in Stem Cell Reports in June 2014.

The use of silicone immersion objectives for long-term 3D live-cell imaging of a MethylRO mouse early embryo during preimplantation development

1)Creating MethylRO mice to visualize epigenetic changes in living cells

Researchers generated a fluorescent probe by fusing a red fluorescent protein to the methyl-CpG binding domain (MBD) of methyl-CpG binding domain protein 1 (MBD1), which recognizes methylated DNA. They then inserted the gene by targeting the ROSA26 locus, which is known for its ubiquitous gene expression, and generated the MethylRO mouse, a genetically modified mouse strain expressing this probe throughout the entire body.

Figure 1. Neonate MethylRO mouse for visualization of methylated DNA (yellow arrows). When irradiated with the excitation light, the entire body glows red through a filter (right panel).
Figure 1. Neonate MethylRO mouse for visualization of methylated DNA (yellow arrows).
When irradiated with the excitation light, the entire body glows red through a filter (right panel).

2)Long-term 3D live-cell imaging of an early embryo during preimplantation development using a 60X silicone immersion objective

Dr. Yamagata and his collaborators used a confocal microscope for time-lapse 3D live-cell imaging of cells from a MethylRO mouse (Fig. 1) during early development of the preimplantation embryo over approximately 4 days.
The researchers used an Olympus silicone immersion objective designed for live cell observation. Silicone oil has a refractive index (ne≈1.40) close to that of living tissue (ne≈1.38). Spherical aberration, which occurs with oil or water immersion objectives due to a refractive-index mismatch with biological samples, is reduced in silicone immersion objectives, allowing researchers to achieve deep, high-contrast fluorescence imaging at a greater depth. In addition, silicone oil does not dry out or become solid, compared to water or oil immersion, when used in a warm (37 °C) environment over 4 days, thereby supporting long-term, stable high-resolution 3D live-cell imaging.
Dr. Yamagata’s team previously used an oil lens and water immersion objective, the former standard for deep observation in live-cell imaging. By switching to a silicone immersion objective, the researchers were able to view fluorescently labeled methylated DNA (mCherry-MBD-NLS) within the nuclei from the surface to the inner region over approximately 4 days from the one-cell zygote to blastocyst stage.

Figure 2. Live-cell imaging of a MethylRO embryo during pre-implantation development. Changes in methylated DNA (mCherry-MBD-NLS) within the nuclei were observed over approximately 4 days.
Figure 2. Live-cell imaging of a MethylRO embryo during pre-implantation development.
Changes in methylated DNA (mCherry-MBD-NLS) within the nuclei were observed over approximately 4 days.

Movie1. Time-lapse imaging over 82 hours of changes in methylated DNA in the nuclei (red: mCherry-MBD-NLS) and cells (green: CAG-EGFP).
Activation of embryonic genes (red) started from the two-cell stage in approximately 21 hours from the beginning of observation.

Movie2. Three-dimensional image of methylated DNA (mCherry-MBD-NLS) within nuclei of a blastocyst

Figure 2 and Movie 1 above show that fluorescence photobleaching during long-term imaging was negligible, enabling clear imaging of methylated DNA within the nuclei. In Movie 2, a three-dimensional image of the entire 100 mm blastocyst was successfully obtained using an objective with both a high numerical aperture (1.3) and long working distance (0.3 mm)

Conclusion: The use of silicone immersion objectives is essential for the realization of deep, high-contrast 3D live-cell imaging over long periods of time.

Olympus’ line-up of 30/40/60/100X silicone immersion objectives offers both high numerical aperture (NA) and long working distance. Since the refractive index of silicone oil (ne≈1.40) is close to that of living tissue (ne≈1.38), spherical aberration induced by a refractive-index mismatch is reduced when observing thick tissues, thereby enabling high-resolution imaging. In addition, silicone oil does not dry out so there is no need to add more immersion liquid during an experiment. The silicone immersion objectives are compatible with the IX motorized inverted microscope series’ Z-Drift Compensation System IX-ZDC. With this system, researchers can obtain images that are constantly in focus and unaffected by temperature changes during long-term observation. In addition, the refractive index of silicone oil (ne≈1.40) and that of SCALEVIEW-A2 (ne≈1.38), an optical clearing agent supplied by Olympus, are comparable, minimizing refractive index mismatch when using this reagent. Silicone immersion objectives with high NA provide optimum performance when optically cleared specimens are used.

Imaging conditions
Imaging system: Research inverted microscope IX series
Objective: silicone immersion objective UPLSAPO60XS
Confocal scanner unit: CSU-X1 (Yokogawa Electric Corporation)
EMCCD camera: iXON3 DU897E-CS0 (Andor Technology)

This application note was prepared with the help of
Dr. Kazuo Yamagata, Associate Professor, Department of Genetic Engineering, Faculty of Biology-Oriented Science and Technology, Kinki University

For more details on the studies in this application note, please refer to the article below:

Ueda, Jun, Kazumitsu Maehara, Daisuke Mashiko, Takako Ichinose, Tatsuma Yao, Mayuko Hori, Yuko Sato, Hiroshi Kimura, Yasuyuki Ohkawa, and Kazuo Yamagata. "Heterochromatin dynamics during the differentiation process revealed by the DNA methylation reporter mouse, MethylRO." Stem cell reports 2, no. 6 (2014): 910-924.

Products Related to This Application

Spinning Disk Confocal Super Resolution Microscope

SpinSR10

  • Live cell super resolution imaging
  • Observation at depth
  • A flexible system that helps simplify your research
The fully-motorized and automated inverted microscope system

IX83

  • Unique deck system
  • Fully-motorized system
  • System solutions
Super Resolution Microscope System

IXplore IX83 SpinSR

The IXplore SpinSR system is our confocal super resolution microscope optimized for 3D imaging of live cell specimens. Like the IXplore Spin system, it has a spinning disk system for fast 3D imaging while limiting phototoxicity and bleaching. However, it achieves super resolution images down to 120 nm XY and enables you to switch between widefield, confocal, and super resolution with the click of a button.

  • Sharp, clear super resolution imaging down to 120 nm XY, owing to Olympus Super Resolution (OSR)
  • Prolonged cell viability in confocal time-lapse imaging due to less phototoxicity and bleaching
  • Use two cameras simultaneously to achieve fast, two-color super-resolution imaging
  • Super resolution imaging with the world’s first plan apochromat objectives with a numerical aperture (NA) of 1.5*
* As of November 2018. According to Olympus research.
TIRF Imaging Microscope System

IXplore IX83 TIRF

For membrane dynamics, single-molecule detection, and colocalization experiments, the IXplore TIRF system enables sensitive simultaneous multicolor TIRF (total internal reflection fluorescence) imaging for up to four colors. Olympus’ cellTIRF system provides stable motorized individual laser-angle control, providing equal evanescent wave penetration for high-contrast, low noise images. Our TIRF objectives feature high SNR, high NA, and correction collars to adjust for cover glass thicknesses and temperature.

  • Exact colocalization of up to four markers thanks to individual penetration depth control
  • Take advantage of Olympus’ TIRF objective with the world's highest NA of 1.7*
  • Intuitive setup of complex experiments with the Graphical Experiment Manager (GEM), cellFRAP, and U-RTCE
* As of July 25, 2017. According to Olympus research.
Live Cell Imaging Microscope System

IXplore Live

Designed to reduce photobleaching and phototoxicity, the IXplore Live system is optimized for physiological experiments involving live cell and tissue observation. Offering precise environmental control and enhanced rigidity, it supports long-term cell viability and stability for time-lapse imaging applications, such as in cancer, stem cell, and brain research.

  • Maintain focus accurately and reliably in time-lapse experiments with TruFocus™ Z-drift compensation system
  • Discover the real morphology of your cells with Olympus silicone immersion optics
  • Real-time controller helps limit cell disturbance, enabling physiologically relevant data
Automated Microscope System

IXplore Pro

The IXplore Pro automated system acquires panoramic, multichannel images without a complex workflow. Easing experiment setup, the Graphical Experimental Manager offers fully automated multidimensional observation capabilities. The microscope’s high-precision ultrasonic stage, automated focusing, and bright, uniform fluorescence illumination facilitate image stitching applications.  

  • Automated multidimensional observation (X, Y, Z, T, wavelength, and positions)
  • Boost your statistics with multiwell plate screening
  • Acquire fluorescence panoramic images of large samples, such as brain slices
  • Create 3D optical sections and enhance resolution with TruSight™ deconvolution
Confocal Imaging Microscope System

IXplore Spin

The IXplore Spin system features a spinning disk confocal unit that enables fast 3D image acquisition, a large field of view, and prolonged cell viability in time-lapse experiments. Researchers can use it to perform rapid 3D confocal imaging with high resolution and contrast at greater depths for imaging into thicker samples. The spinning disk also helps to cut down on photobleaching and phototoxicity of samples upon excitation.

  • Real-time controller (U-RTCE) helps optimize the device’s speed and precision during automated acquisition
  • TruFocus™ Z-drift compensation system maintains focus for each frame
  • Precise 3D imaging with improved light collection using X Line™ objectives
  • Upgrade to the IXplore SpinSR super resolution system as your research progresses
Super Apochromat Objectives

UPLSAPO-S/UPLSAPO-W

These super apochromat objectives provide spherical and chromatic aberration compensation and high transmission from the visible to the near infrared. Using silicone oil or water immersion media, which have refractive indexes closely matching that of live cells, they achieve high-resolution imaging deep in living tissue. 

  • Compensate for both spherical and chromatic aberrations and high transmission from the visible to the near-infrared region
  • Silicone oil or water immersion media help achieve high-resolution imaging deep in living tissue and reduce spherical aberration as their refractive indexes closely match that of live cells