Importance of Accurate Cell Counting in Differentiation of Nerve Cells: iPS PORTAL, Inc.


  • “Human induced pluripotent stem cells (iPSCs) can provide a promising source of mid-brain dopaminergic neurons for cell replacement therapy used to treat Parkinson’s disease. Prior to the clinical application of human iPSCs, it is critical to eliminate tumorigenic or inappropriate cells and to enrich the dopaminergic progenitor cells. This can be achieved with cell sorting using a cell surface antigen, CORIN. Cell densities at passage and the initiation of differentiation are determined by a protocol, indicating the importance of accurate cell counting. Precise counting of iPSC cultures by traditional hemocytometer is difficult because of colony formation. Using the Olympus Cell Counter model R1, cells are properly identified regardless of whether they are single cells or colonized, enabling researchers to conduct experiments with high reproducibility and speed. Furthermore, a microscope with high resolution such as Olympus FV3000 is useful for identification of iPSCs and iPSC-derived cells via immunostaining of cell surface markers or transcription factors. We anticipate that the lineup of Olympus products will prove valuable to many aspects of iPSC research.”
  • Counting of cells (density)
    Cell counter
  • Observation of cell morphology
    Phase-contrast microscope
  • Detection of CORIN+ signal
    Confocal laser scanning microscope

  • iPS Portal Inc provides many solutions for drug discovery and regenerative medicine through its Nobel Prize winning state-of-art iPS cell technologies. Olympus Corporation collaborates with iPS Portal Inc through the Instrument Evaluation Services.

  • For research use only.

Differentiation of iPSC-Derived Nerve Cells Depends on Initial Cell Density.

Experimental Results

  • Positive Control group
     

    5 x 106 cells/well
  • Initiation of Differentiation group
    Differentiation was started and cells were counted and placed into positive and negative control groups based upon concentration.

    Cell counter
  • Negative Control group
     

    1 x106 cells/well
  • Normal cell morphology was observed
  • On Differentiation Culture Day 2
    Phase-contrast images were obtained on differentiation culture day 2. In the positive control group (differentiation was started at a density of 5 x 106 cells/well), normal cell morphology was observed. While, in the group where differentiation was started at a density of 1 x 106 cells/ well, cell morphology was distinctly different from the control group.

    Phase-contrast microscope
  • Abnormal cell morphology was observed
  • CORIN+ signal (green) with reasonable intensity and CORIN+ cell ratio was detected
  • On Differentiation Culture Day 12
    Immunostaining was performed by the use of anti-CORIN antibody. In the positive control group, normal CORIN positive (CORIN+) signal with reasonable signal intensity and the percentage of CORIN+ cells was observed. While, in the group where differentiation was started at a density of 1 x 106 cells/well, signal intensity and the percentage of CORIN+ cells were lower than those of control group, although CORIN+ signal was observed.

    Confocal laser scanning microscope
  • CORIN+ signal was lower than that of control group

Conclusion

After day 12 of differentiation, sorted CORIN+ cells form spheroids maturating toward dopaminergic neurons. The efficiency of inducing differentiation to dopaminergic neurons depends on the density of the sorted CORIN+ cell at initiation, indicating the importance of an accurate cell count.
Sample preparation, image acquisition and data are courtesy of iPS PORTAL Inc.
Banner image: Human iPSC colony
Image data are courtesy of Isao Asaka, Ph.D. Center for iPS Cell Research and Application. Dept. of Fundamental Cell Technology, Kyoto University.

Products used for this application

Confocal Laser Scanning Microscope

FV3000

  • Available with either galvanometer-only (FV3000) or hybrid galvanometer/resonant (FV3000RS) scanner configurations
  • New highly efficient and accurate TruSpectral detection on all channels
  • Optimized for live cell imaging with high sensitivity and low phototoxicity
소형의 인체공학적 세포 배양 솔루션

CKX53

중점 조절이 필요 없는 위상차
반전 대비(Inversion Contrast, IVC) 기술은 선명한 3차원 보기를 제공합니다.
형광과 3구 슬라이더

자동 세포 계수기(Automated Cell Counter)

세포 계수기(Cell Counter) 모델 R1

  • 정확한 세포 계수를 위한 전용 소프트웨어
  • 혁신적인 자동 초점(Autofocus) 리퀴드 렌즈 기술
  • 사용자 친화적 디자인

성공적으로 즐겨찾기에 추가하였습니다.

즐겨찾기닫기

Maximum Compare Limit of 5 Items

Please adjust your selection to be no more than 5 items to compare at once

Sorry, this page is not
available in your country.

This site uses cookies to enhance performance, analyze traffic, and for ads measurement purposes. If you do not change your web settings, cookies will continue to be used on this website. To learn more about how we use cookies on this website, and how you can restrict our use of cookies, please review our Cookie Policy.

OK