Not Available in Your Country
Sorry, this page is not
available in your country.
Características
The Olympus IX83 inverted microscope has been integrated into our IXplore systems. IXplore Systems are designed to provide solutions-based packages that suit your research application needs. |
Expandable to Meet Growing Research NeedsThe fully-motorized IX83 is designed to satisfy a variety of research needs. With additional modules providing expanded functionality, both microscope options enable a multitude of imaging techniques, ranging from casual documentation to long-term time-lapse imaging and other demanding techniques. |
IX83: Two-deck SystemEnables high-speed, fully automated device selection during live cell research and advanced image acquisition. The two-deck configuration provides excellent expandability. | IX83: One-deck SystemAn intelligent, motorized microscope featuring a large field number (FN22, left side port) and TruFocus compatibility, thus creating a new standard for live cell imaging. |
Need assistance? |
Especificações
Método de observação > Fluorescência (Excitação azul/verde) | ✓ | |
---|---|---|
Método de observação > Fluorescência (excitação ultravioleta) | ✓ | |
Método de observação > Contraste de interferência diferencial (DIC) | ✓ | |
Método de observação > Contraste de fase | ✓ | |
Método de observação > Campo claro | ✓ | |
Foco > Motorizado |
| |
Foco > Compensador de desvio Z | ✓ | |
Tubos de observação > Campo amplo (FN 22) > Tubo binocular com inclinação variável | ✓ | |
Tubos de observação > Campo amplo (FN 22) > Trinocular | ✓ | |
Platina > Motorizado | Contact your local sales representative to hear about motorized stage options | |
Platina > Manual > Platina simples | ✓ | |
Platina > Mecânico > Platina mecânica IX3-SVR com pega à direita |
| |
Condensador > Motorizado > Condensador universal | NA 0.55/ W.D. 26.2mm | |
Condensador > Manual > Condensador universal | Dry: NA 0.9/ W.D. 1.5 mm, Oil: NA 1.4/ W.D. 0.63 mm (1.25 X - 100 X) | |
Condensador > Manual > Condensador com distância de trabalho ultra longa | NA 0,3/D.T. 73,3 mm | |
Dimensões (L × D × A) | 323 (W) x 475 (D) x 686 (H) mm (1 Deck Standard Configuration) | |
Peso | 47 kg (1 Configuração padrão de tabuleiro) |
Aplicação
Light-induced Oscillatory/Sustained Expression of Ascl1 in Neural Progenitor Cells.
For generating oscillatory expression of transgene, blue-light was illuminated for 1 min with a 3-hr interval, which maintaining proliferating NPCs.For achieving sustained expression of transgene, blue-light was illuminated for 2 min with a 30-min interval which promoting neuronal fate determination.
Image data courtesy of: Itaru Imayoshi and Ryoichiro Kageyama Institute for Virus Research, Kyoto University |
Reference material:
Itaru Imayoshi, Akihiro Isomura, Yukiko Harima, Kyogo Kawaguchi, Hiroshi Kori, Hitoshi Miyachi, Takahiro Fujiwara, Fumiyoshi Ishidate, and Ryoichiro Kageyama "Oscillatory Control of Factors Determining Multipotency and Fate in Mouse Neural Progenitors" Science 1242366 Published online 31 October 2013.
Synthetic ERK Activity Propagation by A Light-Switchable System
Reference:
Kazuhiro Aoki, Yuka Kumagai,Atsuro Sakurai,Naoki Komatsu,Yoshihisa Fujita,Clara Shionyu,Michiyuki Matsuda. "Stochastic ERK Activation Induced by Noise and Cell-to-Cell Propagation Regulates Cell Density-Dependent Proliferation" Molecular Cell,17 October 2013.
Real-time Imaging for Ring1BYFP/YFP ME
Constitutive exchange of Ring1B-YFP at the PRC1 clusters. A PRC1 cluster in Ring1B YFP/YFP MEFs was subjected to photo-bleaching and subsequent sequential imaging.
Image data courtesy of: Kazuhiro Aoki and Michiyuki Matsuda Imaging Platform for Spatio-Temporal Information, Graduate School of Medicine, Kyoto University | |
Constitutive exchange of Ring1B-YFP at the PRC1 clusters. A PRC1 cluster in Ring1B YFP/YFP MEFs was subjected to photo-bleaching and subsequent sequential imaging.
Image data courtesy of: Kyoichi Isono, and Haruhiko Koseki Laboratory for Developmental Genetics, RIKEN Center for Integrative Medical Sciences (IMS-RCAI) |
Reference:
SAM domain polymerization links subnuclear clustering of PRC1 to gene silencing. Isono K, et al. Developmental Cell, 26, 565-577 (2013).
Brain Slice Culture Glia Cell
Image data courtesy of:
Masafumi Minami Department of Pharmacology, Graduate School of Pharmaceutical Science, Hokkaido University |
Trans-mesenteric Migration of Enteric Neural Crest Derived Cells (ENCCs)
Image data courtesy of:
Hideki Enomoto Neuronal Differentiation and Regeneration, RIKEN CENTER FOR DEVELOPMENT BIOLOGY |
Recursos
Componentes Relacionados
Componentes
Color Cameras
Monochrome Cameras
As câmeras CCD com multiplicação de elétrons amplificam os sinais ópticos sem aumentar o ruído. Elas conseguem capturar imagens de alta velocidade de espécimes escuros e têm bom desempenho na formação imagem de fluorescência de células vivas com luz de excitação de intensidade reduzida. São usadas para observar a interação das proteínas no interior de uma célula e para a formação de imagem em tempo real.
- Tecnologia CCD para detecção de luz ultrabaixa
- Plataforma de câmera científica ultrassensível e dedicada
- Formação de imagem quantificável e reproduzível
Software
Fornecendo operações intuitivas e um fluxo de trabalho automático, a interface do usuário do software cellSens é personalizável e, assim, você controla o layout. Oferecido em uma série de pacotes, o software cellSens fornece uma variedade de recursos otimizados para as suas necessidades de formação de imagem específicas. Os recursos de Gerenciador de experimento gráfico e Navegador de poços facilitam a aquisição de imagem 5D. Obtenha uma resolução melhorada com a deconvolução TruSight™ e compartilhe suas imagens usando o modo de Conferência.
- Melhore a eficiência dos experimentos com a análise de segmentação com aprendizado profundo TruAI™, que fornece uma detecção de núcleos sem marcação e a contagem de células
- Plataforma de software de formação de imagem modular
- Interface do usuário orientada para a aplicação intuitiva
- Vasto conjunto de recursos, variando de uma simples imagem única a experimentos avançados multidimensionais em tempo real
Advanced Imaging Solutions (systems)
Light Sources
Facilitando as aplicações de fluorescência, esse sistema de iluminação com guia de luz acoplada reduz os efeitos térmicos e a vibração. É fácil de instalar e fornece uma excelente estabilidade a longo e curto prazo. Uma íris de seis fases controla eficazmente a intensidade e permite um ajuste de intensidade em etapas simples, e o seu queimador pré-centralizado reduz os custos de operação.
- Queimador de 130 W potente com vida útil longa
- Saída de luz estável e uniforme
- Iluminação uniforme sem alinhamento