Evident LogoOlympus Logo

Caractéristiques

Laser Unit > Qualified IR Pulsed Laser with Negative Chirp for Multiphoton Excitation

Mode-locked Ti: sapphire laser [femtosecond laser (equipped with a group velocity compensation)], laser power unit, water-cooled circulating chiller

MaiTai BB DeepSee-OL, MaiTai HP DeepSee-OL or MaiTai eHP DeepSee-OL (Spectra-Physics products)
MaiTai BB DeepSee-OL: 710 nm - 990 nm
MaiTai HP DeepSee-OL: 690 nm - 1040 nm
MaiTai eHP DeepSee-OL: 690 nm - 1040 nm (70 femtoseconds at a specimen plane)

Chameleon Vision I-OL, Chameleon Vision II-OL (Coherent products)
Chameleon Vision I-OL: 690 nm - 1040 nm
Chameleon Vision II-OL: 680 nm - 1080 nm

Laser Unit > Automatic Introduction Optic

AOTF (B, S, T system)
Continuously variable 
(0.1 % - 100 %, 0.1 % increment)
REX: Capable of laser intensity adjustment and laser wavelength selection for each region.

Laser Unit > Optional Visible Light Laser for Stimulation

LD473 laser (15 mW) Depending on the type of modulation: light intensity modulation, shutter control, connected to the
scanner via single-mode optical fi ber. (B, S, T system)

Laser Unit > LD Laser for Visible Light > 405 nm
  • 50 mW (systèmes B, S, T)
Laser Unit > LD Laser for Visible Light > 440 nm
  • 25 mW (systèmes B, S, T)
Laser Unit > LD Laser for Visible Light > 473 nm
  • 15 mW (systèmes B, S, T)
Laser Unit > LD Laser for Visible Light > 559 nm
  • 15 mW (systèmes B, S, T)
Laser Unit > LD Laser for Visible Light > 635 nm
  • 20 mW (systèmes B, S, T)
Laser Unit > Multiline Argon Laser (457 nm, 488 nm, 515 nm, Total 30 mW)
  • ✓ (systèmes B, S, T)
Laser Unit > HeNe(G) Laser (543 nm, 1 mW)
  • ✓ (systèmes B, S, T)
Scanning and Detection > Main Scanner > Standard Laser Ports
  • 1 (système M)
  • 3 (systèmes B, S, T)
Scanning and Detection > Main Scanner > Detector > Standard
  • Photomultiplicateur Multi alcali (2 ou 4 canaux)
Scanning and Detection > Main Scanner > Detector > Cooled GaAsP-PMT 2 CH
  • Photomultiplicateurs GaAsP refroidis 2 canaux plus photomultiplicateur multi alcali 2 canaux
Scanning and Detection > Main Scanner > Detector > Optional 4 CH
  • ✓ (systèmes B, S, T)
Scanning and Detection > Main Scanner > Photo Detection Method > Analog Integration
Scanning and Detection > Main Scanner > Photo Detection Method > Hybrid Photon Counting
Scanning and Detection > Main Scanner > VIS - UV - IR Excitation Dichromatic Mirror Turret
  • 6 positions (DM haute performance et demi-miroir 20/80) (Systèmes B, S, T)
Scanning and Detection > Main Scanner > Beamsplitter Turrets
  • 6 positions avec CH1 et CH2 (système B, S, T)
Scanning and Detection > Main Scanner > Wavelength Selection

<Spectral type> (B, S, T system)
CH1 and CH2 equipped with independent grating and slit for fast and flexible spectral detection
Selectable wavelength bandwidth: 1 – 100 nm
Wavelength resolution: 2 nm
Wavelength switching speed: 100 nm/ ms
CH3 with 6 positions barrier filter turret
<Filter type>  (B, S, T system)
CH1 to CH3 each with 6 positions barrier filter turret (High performance filters)

Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Galvanometer Mirror Scanner (X, Y)
  • Scanner double
  • Revêtement en argent anti-oxydation (systèmes B, S, T)
  • Dorure anti-oxydation (système M)
Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Modes > 2D

<Spectral type>
XY, XZ, XT, Xλ
<Filter type>
XY, XZ, XT

Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Modes > 3D

<Spectral type>
XYZ, XYT, XYλ, XZT, XTλ, XZλ
<Filter type>
XYZ, XYT,  XZT

Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Modes > 4D

<Spectral type>
XYZT, XZTλ, XYTλ
<Filter type>
XYZT

Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Modes > 5D

<Spectral type>
XYZTλ
<Filter type>
-

Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Modes > Other

Line scanning: Straight line with free orientation, free line, Point scanning

Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Speed
  • Mode standard : temps par pixel variable ~ 2 µs - 200 µs
Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Pinhole

<Spectral type>
Single motorized
Diameter ø50 – 300 μm (1 μm step)
<Filter type>
Single motorized
Diameter ø50 – 800 μm (1 μm step)

Scanning and Detection > Galvanometer Scanner (Normal Imaging) > Scanning Zoom
  • 1 X - 50 X par incréments de 0,1 X
Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Modes > 2D

-

Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Modes > 3D

-

Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Modes > 4D

-

Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Modes > 5D

-

Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Modes > other

-

Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Speed

-

Scanning and Detection > Resonant Scanner (High-Speed Imaging) > Scanning Zoom

-

Scanning and Detection > Field Number (NA)
  • 18
Scanning and Detection > Z-Drive
  • Un module de mise au point motorisée dans le microscope est utilisé
  • Incrément minimum : 0,01 μm
Scanning and Detection > Transmitted Light Detector Unit

Photomultiplier (2 channels), fluorescent detector Fluorescence wavelength can be selected with the dedicated filter cube (replaceable)
Exclusive equipment for the BX61WI upright microscope

Microscope > Frame
  • BX61
  • BX61WI
Microscope > Frame > Inverted
  • IX83 (IX83P2ZF)
Microscope > Objectives and Focus > Objectives
  • -
Microscope > Objectives and Focus > Auto Focus (AF)
  • -
Microscope > Objectives and Focus > Water Supply
  • -
Microscope > Objectives and Focus > Oil Supply
  • -
Microscope > XY Stage > Specimen Holder
  • -
Microscope > Incubator > Room Environment
  • -
Microscope > Incubator > Heating Method
  • -
System Control > Controller
  • SE : Windows 7 Professional (version anglaise)
System Control > Power Supply Unit

-

System Control > Monitor
  • -
Optional Unit > SIM Scanner
Optional Unit > TIRFM Unit
  • -
Software > Image Acquisition

-

Software > Programmable Scan Controller

-

Software > 2D Image Display

-

Software > 3D Visualization and Observation

-

Software > Image Format

-

Software > Spectral Unmixing

-

Software > Image Processing

-

Software > Image Analysis

-

Software > Statistical Processing

-

Software > Optional Software

-

Software > Image Acquisition Mode

-

Software > Map Image Acquisition

-

Software > Multi Area Time-Lapse

-

Software > Image Acquisition Area

-

Software > Image Display
  • -
Software > Cross Talk Reduction

-

Software > Acquisition Image File Type
  • -
Software > Image File Type Available for Viewing
  • -
Software > Image Editing

-

Software > 3D Image Construction

-

Software > Basic Features

-

Software > IR Laser Controlling
  • -
Software > Optional Motorised-Stage Software

-

Software > Optional Mapping and Multiplepoint Simulation Software

-

Software > Optional Sequencer Manager

-

Dimensions, Weight and Power Consumption > Microscope with Scan Unit > Dimensions (mm)
  • Taille de la table isolée contre les vibrations :
  • Systèmes B et M : 1 500 mm x 1 250 mm
  • Système S : 1 500 mm x 1 500 mm
  • Système T : 1 700 mm x 1 700 mm
Dimensions, Weight and Power Consumption > Microscope with Scan Unit > Weight (kg)
  • -
Dimensions, Weight and Power Consumption > Microscope with Scan Unit > Power Consumption
  • -
Dimensions, Weight and Power Consumption > Fluorescence Illumination Unit > Dimensions (mm)
  • Lampe : 180 (L) x 320 (P) x 235 (H)
  • Alimentation électrique : 90 (L) x 270 (P) x 180 (H)
Dimensions, Weight and Power Consumption > Fluorescence Illumination Unit > Weight (kg)
  • Lampe : 6,7
  • Alimentation électrique : 3,0
Dimensions, Weight and Power Consumption > Fluorescence Illumination Unit > Power Consumption
  • Alimentation électrique : AC 100-240 V 50/60 Hz 1,6 A
Dimensions, Weight and Power Consumption > Transmitted Light Detection Unit > Dimensions (mm)
  • 170 (L) x 330 (P) x 130 (H)
Dimensions, Weight and Power Consumption > Transmitted Light Detection Unit > Weight (kg)
  • 5,9
Dimensions, Weight and Power Consumption > Transmitted Light Detection Unit > Power Consumption
  • -
Dimensions, Weight and Power Consumption > Microscope Control Unit > Dimensions (mm)
  • 125 (L) x 332 (P) x 216 (H)
Dimensions, Weight and Power Consumption > Microscope Control Unit > Weight (kg)
  • 5,2
Dimensions, Weight and Power Consumption > Microscope Control Unit > Power Consumption
  • AC 100-120/220-240 V 50/60 Hz 3,5 A/1,5 A
Dimensions, Weight and Power Consumption > FV Power Supply Unit > Dimensions (mm)
  • 180 (L) x 328 (P) x 424 (H)
Dimensions, Weight and Power Consumption > FV Power Supply Unit > Weight (kg)
  • 7,5
Dimensions, Weight and Power Consumption > FV Power Supply Unit > Power Consumption
  • AC 100-120/220-240 V 50/60 Hz 4,0 A/2,0 A
Dimensions, Weight and Power Consumption > Power Supply Unit for Laser Combiner > Dimensions (mm)
  • 210 (L) x 300 (P) x 100 (H) (système B, S, T)
Dimensions, Weight and Power Consumption > Power Supply Unit for Laser Combiner > Weight (kg)
  • 4
Dimensions, Weight and Power Consumption > Power Supply Unit for Laser Combiner > Power Consumption
  • AC 100-120/220-240 V 50/60 Hz 2,0 A/1,0 A
Dimensions, Weight and Power Consumption > Laser Combiner (with Ar Laser Heads) > Dimensions (mm)
  • 514 (L) x 504 (P) x 236 (H) (système B, S, T)
Dimensions, Weight and Power Consumption > Laser Combiner (with Ar Laser Heads) > Weight (kg)
  • 40
Dimensions, Weight and Power Consumption > Laser Combiner (with Ar Laser Heads) > Power Consumption
  • -
Dimensions, Weight and Power Consumption > Laser Combiner (without Ar Laser Heads) > Dimensions (mm)
  • 514 (L) x 364 (P) x 236 (H) (système B, S, T)
Dimensions, Weight and Power Consumption > Laser Combiner (without Ar Laser Heads) > Weight (kg)
  • 40
Dimensions, Weight and Power Consumption > Laser Combiner (without Ar Laser Heads) > Power Consumption
  • -
Dimensions, Weight and Power Consumption > LD559 Laser Power Supply > Dimensions (mm)
  • 200 (L) x 330 (P) x 55 (H) (système B, S, T)
Dimensions, Weight and Power Consumption > LD559 Laser Power Supply > Weight (kg)
  • 1,2
Dimensions, Weight and Power Consumption > LD559 Laser Power Supply > Power Consumption
  • AC 100-240 V 50/60 Hz 30 W
Dimensions, Weight and Power Consumption > Multi Ar Laser Power Supply > Dimensions (mm)
  • 162 (L) x 287 (P) x 91 (H) (système B, S, T)
Dimensions, Weight and Power Consumption > Multi Ar Laser Power Supply > Weight (kg)
  • 4,4
Dimensions, Weight and Power Consumption > Multi Ar Laser Power Supply > Power Consumption
  • AC 100-240 V 50/60 Hz 20 A
Dimensions, Weight and Power Consumption > HeNe(G) Laser Power Supply > Dimensions (mm)
  • 130 (L) x 224 (P) x 65 (H) (système B, S, T)
Dimensions, Weight and Power Consumption > HeNe(G) Laser Power Supply > Weight (kg)
  • 1,8
Dimensions, Weight and Power Consumption > HeNe(G) Laser Power Supply > Power Consumption
  • AC 200-240 V 50/60 Hz 0,23 A
Dimensions, Weight and Power Consumption > Operating Environment (Indoor Use) > Ambient TemperatureTempérature de la pièce : 20 - 25 ℃
Dimensions, Weight and Power Consumption > Operating Environment (Indoor Use) > Maximum Relative Humidity75 % ou moins à 25 °C nécessite une alimentation en continu (24 heures)

Sorry, this page is not
available in your country.

Sorry, this page is not available in your country